PepLabo Download

GLP-1 injection problems: leaks, blood, bubbles and clicks

Medication leaked after a GLP-1 shot, a drop on the needle, blood, air bubbles or no click: what the Ozempic, Wegovy and Mounjaro pen instructions say.

Published · Updated · GLP-1 medications · Written by the PepLabo editorial team

When to get help
Context and scope

Most injection worries come down to a handful of moments: a drop on the needle, a wet patch of skin afterwards, a spot of blood, an air bubble, a click that did not come. The manufacturers’ Instructions for Use (IFU) answer many of them directly, and the answers differ between a single-dose pen and a pen you dial. This article collects what the Ozempic®, Wegovy® and Mounjaro® instructions say, what the FDA and the Institute for Safe Medication Practices have seen go wrong, and when to ask your pharmacist or prescriber.

Key takeaways 4
  • For bleeding, all three instructions say the same: press lightly with a gauze pad or cotton ball and do not rub [1][2][3].
  • The Ozempic® pen needs a flow check with each new pen only; if 0 does not appear on the counter during an injection, a blocked needle may mean no medicine was given [1].
  • FDA and ISMP list forgetting the inner needle cap and “priming” a Trulicity® single-dose pen, which empties it, among reported pen errors [4].
  • A review of injection pain names needle size, site, volume, speed, cold solutions and some ingredients as factors; volumes up to 0.5 to 0.8 mL are not expected to add much pain [5].

Which instructions apply to your pen?

GLP-1 medicines come in pens that work in different ways, and the same event can mean different things in each. A single-dose pen such as Wegovy® or Mounjaro® has a hidden, attached needle and gives one fixed dose; a dial-a-dose pen such as Ozempic® takes a new needle each time and needs a dose set on a counter [1][2][3]. The FDA’s advice in its presentation on pen injectors is to read the product-specific label and instructions, because pens that share a design still differ in certain features [4].

This page quotes the instructions for those three pens. If yours is a different pen, a vial or a KwikPen®, its own IFU is the one to follow; our article on how GLP-1 pens work walks through the device types.

Is a drop of liquid on the needle normal?

Yes, according to the instructions. The Mounjaro® IFU says a drop of liquid on the tip of the needle when the gray base cap comes off is normal, and asks you not to touch the needle [2].

The Ozempic® IFU says a drop may appear when the inner needle cap is removed, and that this is normal, but a new pen still needs its flow check before its first injection [1]. That check is meant to produce a drop: if none appears after up to 6 tries, and one more try with a new needle, the pen should not be used and Novo Nordisk should be contacted [1]. After an injection, the same IFU says a drop at the needle tip is normal and does not affect your dose [1].

Medicine on the skin or leaking after the injection

The instructions draw a line between a small drop and a stream. The Mounjaro® IFU calls a drop of liquid or blood on the skin after the injection normal [2].

A stream is different. The Wegovy® IFU says medicine may appear on the skin or squirt from the needle, and you may not get your full dose, if the pen is removed too early or not pressed firmly against the skin for the whole injection [3]. The Ozempic® IFU asks you to keep the dose button pressed and count 6 seconds after the counter shows 0; if the needle comes out earlier, a stream may come from the tip and the full dose will not be delivered [1].

None of the three instructions tells you to inject a second dose after a leak. The Wegovy® troubleshooting section only says to keep pressing until the yellow bar has stopped next time [3]. If you think you lost part of a dose, ask your pharmacist or prescriber before doing anything else, and note what happened.

What should I do if the site bleeds?

All three instructions give the same step: if blood appears at the injection site, press lightly with a gauze pad or cotton ball, and do not rub the area [1][2][3]. A small spot of blood is listed among the normal events in the Mounjaro® IFU [2].

Bruises, lumps and redness are covered in our article on injection site reactions, including how often they appeared in the trials. One rule from the Wegovy® IFU is worth knowing here: do not inject into skin that is tender, bruised, red or hard [3].

Are air bubbles in the pen a problem?

For the single-dose pens, the instructions say no. The Mounjaro® IFU says air bubbles are normal, and the Wegovy® IFU adds that they do not affect your dose [2][3].

The Ozempic® IFU does not discuss bubbles. Its checks are that the medicine is clear and colourless and, for each new pen, that the flow check produces a drop [1]. All three ask you to check the medicine itself before injecting: clear, not cloudy and free of particles in the Ozempic® and Mounjaro® instructions, clear and colourless for Wegovy® [1][2][3].

The pen did not click, or the counter did not reach 0

Each pen has its own end-of-dose signal, and the instructions say what to do when it is missing.

How each pen shows a complete dose, and what its IFU says if it does not
PenSignal of a complete doseIf the signal is missingSource
Mounjaro® single-dose penSecond loud click and a visible gray plunger; a soft click just before the second loud click is normalIf you do not see the gray plunger, contact Lilly for instructions and store the pen safely[2]
Wegovy® single-dose penTwo clicks, then the yellow bar stops moving; about 5 to 10 secondsIf the bar does not start, press more firmly; if it does not start or stops, contact your healthcare provider or Novo Nordisk[3]
Ozempic® dial-a-dose penThe dose counter returns to 0, then 6 more seconds with the button heldIf 0 does not appear, the needle may be blocked and no medicine was given; change the needle and repeat from Step 1[1]

Handling errors reported to FDA and ISMP

An FDA and Institute for Safe Medication Practices (ISMP) presentation on pen injectors collects errors seen in practice. Several apply to GLP-1 pens [4].

  • Not removing the inner needle cap on a pen that uses separate needles. The Ozempic® IFU warns that if both caps are not removed, no medicine is injected [1][4].
  • “Priming” a Trulicity® pen as if it were a dial-a-dose pen, which empties it and wastes the whole dose [4].
  • Setting a dose by counting clicks. The Ozempic® IFU says to use the dose counter and pointer instead, because the clicks do not show the dose [1][4].
  • Writing a Victoza® or Saxenda® dose in mL instead of mg; since these pens hold 6 mg per mL, 1.2 mL would be a 6-fold overdose [4].
  • Reusing needles, sharing pens between people, and using a pen after its allowed time out of the refrigerator [4].

Why does an injection sting or burn?

A 2019 review of subcutaneous injection pain lists the factors researchers have measured: needle length and thickness, the injection site, the volume, the injection speed, and properties of the solution such as osmolality, viscosity, pH, buffers and preservatives [5]. Volumes up to 0.5 to 0.8 mL are not expected to add much to the pain of the needle itself [5]; the Mounjaro® single-dose pen holds 0.5 mL and Wegovy® single-dose pens 0.5 or 0.75 mL [2][3].

Temperature is the one factor people often ask about. The review notes that a cold solution can hurt more [5], while the Mounjaro® IFU says it is not necessary to warm the pen to room temperature [2]. Each product has its own limits for time out of the refrigerator, so follow your pen’s storage section rather than a general rule.

The Wegovy® IFU adds a practical point for difficult injections: change to a firmer site, such as the thigh or upper arm, or stand up when injecting into the lower stomach [3]. A burning or tingling feeling in skin away from the injection site is a different matter; it is listed as a side effect in the Wegovy® label, for example, and is worth raising with your prescriber [3].

Near the belly button, a scar or a dropped pen

  • The Wegovy® IFU asks you to keep at least 2 inches away from the belly button and to avoid scars and stretch marks [3].
  • The Mounjaro® IFU says you may use the same body area each week but should choose a different spot within it [2].
  • A Mounjaro® pen dropped on a hard surface should not be used [2]; a Wegovy® pen that looks broken, for example after a fall, should not be used [3]; an Ozempic® pen that was dropped needs a new needle and a flow check before injecting [1].

Ozempic®, Wegovy®, NovoFine®, Saxenda® and Victoza® are registered trademarks of Novo Nordisk A/S. Mounjaro®, KwikPen® and Trulicity® are registered trademarks of Eli Lilly and Company. PepLabo is not affiliated with or endorsed by Novo Nordisk or Eli Lilly and Company.

When to get help

The signs and contact information below come from this article’s sourced guidance.

Emergency

  • Swelling of the face, lips, tongue or throat, trouble breathing or swallowing, severe rash or itching, fainting or a very rapid heartbeat

    Contact: Stop the medicine and get medical help right away

    Mounjaro® Medication Guide [6]

Today

  • A single-dose pen showed no gray plunger, or its yellow bar did not start or stopped

    Contact: The manufacturer’s line or your healthcare provider, before any further dose

    Mounjaro® and Wegovy® IFU [2][3]

  • The Ozempic® counter did not return to 0, or no drop appears in the flow check of a new pen

    Contact: Follow the IFU steps; if the problem remains, contact Novo Nordisk or your pharmacist

    Ozempic® IFU [1]

  • Medicine squirted out and you are unsure how much was given

    Contact: Your pharmacist or prescriber, before injecting again

    Wegovy® and Ozempic® IFU [1][3]

At your next appointment

  • Pain, lumps or bruising that keep coming back at injection sites

    Contact: Your prescriber or pharmacist, to check your technique and sites

    Wegovy® IFU [3]

Questions

Medication leaked after my GLP-1 injection. Did I get my dose?

It depends on how much. A drop of liquid on the skin is called normal in the Mounjaro® IFU [2]. A stream or squirt can mean the pen was lifted too early, and the Wegovy® and Ozempic® instructions say the full dose may then not be delivered [1][3]. Ask your pharmacist or prescriber before injecting again.

Is it normal to see a drop on the needle of my Mounjaro pen?

Yes. The Mounjaro® IFU says a drop of liquid on the needle tip when the gray base cap is removed is normal; do not touch the needle [2].

Are air bubbles in my Wegovy pen dangerous?

The Wegovy® IFU says air bubbles are normal and do not affect your dose [3]. The medicine should still be clear and colourless [3].

I bled after my Ozempic shot. What should I do?

Press lightly on the site with a gauze pad or cotton ball and do not rub, as the Ozempic® IFU says [1]. A bruise or bleeding that keeps returning is worth mentioning to your prescriber.

My Mounjaro pen clicked, but I do not see the gray plunger. What now?

The IFU says the dose was delivered if the gray plunger is visible; if it is not, contact Lilly for further instructions and store the pen safely to avoid a needle stick [2].

Why does my GLP-1 injection sting more some weeks?

A review lists the site, needle, volume, speed and a cold solution among the factors that change injection pain [5]. Rotating sites and avoiding tender, bruised or hard skin are steps from the Wegovy® IFU [3].

Should I take another dose if I think the injection failed?

Only the Ozempic® IFU describes repeating the steps, for a blocked needle that delivered no medicine [1]. The single-dose pen instructions say to contact the manufacturer or your healthcare provider [2][3]. Do not double up on your own.

Sources

Sources checked on

  1. OZEMPIC® (semaglutide) injection, Prescribing Information, Medication Guide and Instructions for Use, Novo Nordisk PI revised 05/2026; Instructions for Use for the 0.25 mg or 0.5 mg pen revised June/2026. Steps 1 to 5, blocked needle and pen care.
  2. MOUNJARO® (tirzepatide) single-dose pen, Instructions for Use, Eli Lilly and Company Revised April 2026. Steps 1 to 4, storage and commonly asked questions.
  3. WEGOVY® (semaglutide) injection, Prescribing Information and Instructions for Use, Novo Nordisk PI revised 06/2026; single-dose pen Instructions for Use revised November 2025. Important information, Steps 2 to 4 and troubleshooting.
  4. FDA Drug Topics: How to Avoid Medication Errors with Pen Injectors. U.S. Food and Drug Administration and Institute for Safe Medication Practices Presentation slides, 2023. Administration errors, autoinjectors versus pen injectors, dosing-unit errors.
  5. Usach I, et al. Subcutaneous Injection of Drugs: Literature Review of Factors Influencing Pain Sensation at the Injection Site. Adv Ther. 2019;36(11):2986–2996 Narrative literature review; full text (PMC6822791). Funded by Sandoz.
  6. MOUNJARO® (tirzepatide) prescribing information and Medication Guide, DailyMed (Eli Lilly and Company) Revised 8/2026. Medication Guide, serious allergic reactions.