PepLabo Download

Units, IU and mL: three different measurements

Syringe units, International Units and millilitres measure different things. How labels use each, and why mixing them up led to FDA-reported overdoses.

Published · Updated · Peptides · Written by the PepLabo editorial team

Context and scope

Conversations about peptides and GLP-1 medicines mix three words that sound alike: the “units” on an insulin syringe, the International Units (IU) on some labels, and millilitres (mL). They measure different things. This article explains each one from regulator and label sources and shows, with FDA reports, what happens when they are confused. It gives no doses and no conversion for any medicine: your label and your pharmacist decide how a dose is measured.

Key takeaways 4
  • On a U-100 insulin syringe, the line marked 5 units holds 0.05 mL; each line is a volume, not an amount of a particular drug. [1]
  • Syringe markings belong to one concentration: the U-500 insulin instructions warn that a U-100 syringe can give a 5-times overdose of U-500 insulin. [5]
  • International Units come from WHO reference preparations that are assigned a potency value; they measure activity, not volume or weight. [2][3]
  • Approved semaglutide is labelled in milligrams in a stated volume; FDA reports describe compounded products dosed in “units” leading to 5- to 20-fold overdoses. [1][7]

What does mL measure?

A millilitre is a unit of volume: how much liquid is in the syringe. MedlinePlus notes that a syringe may be marked in cubic centimetres (cc) while a medicine bottle may say millilitres, and that 1 cc is the same amount as 1 mL [6].

Volume alone says nothing about how much medicine you get. That depends on how much medicine each mL contains, which is why labels state an amount in a volume. The Wegovy® label, for example, describes each pen by the milligrams of semaglutide it contains and the volume they come in [7]. The same volume of two different products can hold very different amounts of medicine.

What are the “units” on an insulin syringe?

An insulin syringe is printed for one particular strength of insulin. A U-100 syringe is made for insulin containing 100 units in each mL, so its full 1 mL barrel is marked as 100 units. The FDA’s own example makes the scale concrete: patients were told to use a U-100 (1 millilitre) insulin syringe to draw a 5-unit dose, which it gives as 0.05 millilitre [1].

For anything other than U-100 insulin, those lines are simply a volume scale in hundredths of a millilitre. They do not count units of the medicine in the syringe unless that medicine happens to contain 100 of its own units per mL.

Insulin itself shows how tightly the markings are tied to concentration. Humulin® R U-500 contains 500 units per mL, and its instructions say to always inject it with a U-500 syringe, on which each line measures 5 units of U-500 insulin. Other syringes will not measure the dose correctly, and the instructions warn that using a U-100 syringe can give a 5-times overdose [5].

What is an International Unit (IU)?

An International Unit is a measure of biological activity, not of volume or weight. The WHO establishes international biological reference standards: physical reference preparations that let laboratories in different countries measure the biological activity of a product in a consistent, comparable way. Where appropriate, a value such as a potency in International Units is assigned to the reference preparation; these standards are for laboratory use only and are never given to people [2].

A peptide label shows how this works in practice. The calcitonin salmon injection label (Miacalcin®) explains that its activity is stated in International Units, based on a bioassay compared with the International Reference Preparation of calcitonin salmon distributed by the UK’s National Institute for Biological Standards and Control [3].

Two consequences follow. An IU of one substance has no fixed relationship to an IU of another, because each is defined by its own reference preparation. And an IU cannot be turned into mL without knowing how many units the particular product contains in each mL.

What is a USP unit, and when is a medicine measured in mg instead?

Some US labels state strength in units defined by the US Pharmacopeia. The calcitonin salmon injection label gives its strength as 200 USP Units per mL [3]. An oxytocin injection label, for a synthetic nonapeptide, states that the product is standardised to contain 10 units of oxytocic hormone per mL [4]. Many other medicines, including the approved semaglutide products, are labelled by weight in milligrams [7].

Which unit applies is not a matter of preference. It is whatever the label of that product uses, and the dose should be written in the same unit.

How four US labels state the amount of medicine (checked 17 November 2026)
ProductWhat it isHow the label states the amount
Calcitonin salmon injection (Miacalcin®)Synthetic polypeptide of 32 amino acids [3]USP Units per mL; activity stated in International Units against an international reference preparation [3]
Oxytocin injection, USPSynthetic nonapeptide [4]Units of oxytocic hormone per mL [4]
Humulin® R U-500Human insulin [5]500 units per mL, measured only with a U-500 syringe [5]
Wegovy® injectionSemaglutide, a GLP-1 receptor agonist [7]Milligrams of semaglutide in a stated volume [7]

Why can’t IU or units be converted to mL on their own?

Because a conversion needs a third number: the concentration of the specific product, in units per mL or milligrams per mL, as printed on its label or vial. The same volume holds different amounts in different products, and even different amounts in two vials of the same substance if they were made at different strengths. The FDA notes that compounded semaglutide was offered in several concentrations, sometimes by the same compounder, and that instructions given in “units” meant a volume that varied with the concentration [1].

An online chart that turns IU into mL without asking for your product’s concentration cannot be right for every product. This article deliberately gives no such conversion.

What went wrong with compounded semaglutide?

In July 2024 the FDA reported adverse events, some requiring hospitalisation, that may have been related to dosing errors with compounded semaglutide injections [1]. Most reports described patients drawing up more than the prescribed dose from a multiple-dose vial, with five to 20 times the intended amount given. In several cases patients told to draw 5 units with a U-100 syringe drew 50 units instead [1].

Health care providers made conversion errors too. The FDA describes one provider who meant to prescribe 5 units but wrote 25, and another who prescribed 20 units instead of 2, affecting three patients [1]. It also says some patients were given syringes much larger than the prescribed volume [1].

The reported effects included nausea, vomiting, abdominal pain, fainting, headache, migraine, dehydration, acute pancreatitis and gallstones [1]. The FDA encourages providers and compounders to supply a syringe sized for the intended dose and to show patients how to measure it [1].

What the PepLabo syringe converter does, and what it does not

The syringe converter on this site does one thing: it turns a volume in millilitres into the matching line on a U-100 syringe, and back. It does not convert International Units, USP units or milligrams, and it is not for U-500 or other syringe types. It suggests no dose; the numbers you enter come from your own label and prescriber.

Questions to ask your pharmacist

  • Is my dose written in milligrams, millilitres, units or International Units, and does the syringe I was given measure that same thing?
  • What concentration does this vial or pen contain, per mL, as printed on its label?
  • Is this the right syringe type for this product: a U-100 insulin syringe, a U-500 syringe or a syringe marked in mL [5]?
  • Can you show me the exact line on my own syringe that matches my dose? The FDA encourages exactly this kind of counselling [1].
  • If my instructions say “units”, do they mean lines on the syringe or units of biological activity?

Humulin® is a trademark of Eli Lilly and Company. Miacalcin® is a registered trademark of Novartis AG. Wegovy® is a registered trademark of Novo Nordisk A/S. PepLabo is not affiliated with or endorsed by Eli Lilly and Company, Novartis or Novo Nordisk.

Questions

How many mL is 1 IU?

There is no single answer. An IU measures biological activity against a WHO reference standard, so how much liquid holds 1 IU depends entirely on the concentration printed on that product’s label [2][3]. Ask your pharmacist for your own product.

Are insulin syringe units the same as IU?

Not in general. U-100 syringe lines are a volume scale in hundredths of a millilitre, made for insulin at 100 units per mL; the FDA gives 5 units on such a syringe as 0.05 mL [1]. For any other liquid they show volume only.

Can I use a U-100 syringe for U-500 insulin?

No. The Humulin® R U-500 instructions say to always use a U-500 syringe and warn that a U-100 syringe can give a 5-times overdose [5].

What is a USP unit?

A unit used in some US labels for medicines measured by their biological effect, such as calcitonin salmon injection at 200 USP Units per mL [3]. Use whichever unit your own label uses.

Why did the FDA warn about units with compounded semaglutide?

Because instructions in “units”, several product concentrations and unfamiliar syringes led to doses five to 20 times higher than intended, some needing hospital care [1].

Is a cc the same as a mL?